Fluke 基礎知識
通過持續獲取良好實踐、實用的操作文章和視頻、福祿克工具基礎知識和一些常見的行業術語,不斷學習與您所在行業相關的知識。無論您是行業新人,還是經驗豐富的資深人士,這些信息都會讓您保持敏銳頭腦,并讓您為需要您大顯身手的那一天做好準備!

基本原理視頻
鉗形表
為什么在太陽能光伏裝置中使用 CAT III 級鉗表?
用于安裝、監測和測試光伏系統的一個關鍵工具是 Fluke 393 FC 太陽能鉗表,其安全等級為 CAT III 1500 V/CAT IV 600 V,適用于包括太陽能裝置的 CAT III 環境。
萬用表
數字萬用表常見問題解答
在現場使用時,由于不同工況下測試環境、現場電氣氛圍、被測設備、信號類型等因素,很多時候萬用表使用時會碰到測試結果偏差大,甚至燒表的情況。這篇文章旨在幫助大家了解萬用表在實際測試過程中,經常會碰到的問題及解決方法。
絕緣測試儀
Insulation resistance testing capacitors and high-voltage components
Using a megger for insulation resistance testing capacitors and high voltage components.
消除潦草的手寫涂鴉并開始使用電機測試數據
如果電機和動力電纜會說話,它們會說些什么呢?它們可能會告訴你什么時間需要維護,或者提醒你時常對其進行檢查。當然,電機不會說話。因此,福祿克開發了Fluke Connect?應用程序,支持手機或平板電腦通過無線方式連接到福祿克絕緣電阻測試儀。憑借方便訪問的數據,您可了解電機的狀態,并與其他位置的同事或專家共享數據。
絕緣測試儀
What is an insulation multimeter?
The Fluke 15x7 Series Insulation Multimeter is a new category of test tool that combines a full featured True RMS DMM and a megohmmeter. It's an integrated tool for maintaining and troubleshooting motor systems, electrical distribution, and production equipment.
Insulation resistance testing capacitors and high-voltage components
Using a megger for insulation resistance testing capacitors and high voltage components.
Insulation tester vs megohmmeter
What is the difference between an insulation tester and a megohmmeter? Compare insulation meters, testers, megohmmeters, and meggers to learn about what's best for your needs.
示波表
How to read a waveform on an oscilloscope
Oscilloscopes sample signals as they change over time and then plot those signals on a display. The amplitude of the signal is plotted on the vertical axis and time is displayed on the horizontal.
電能質量
Detecting power quality issues
The electrical power issues that most frequently affect industrial plants include voltage sags and swells, harmonics, transients, and voltage and current unbalance. The proper tools to correct these issues include knowledge and electrical test instruments ideally suited for each task.
Common Power Quality Factors Affecting Transformers
Transformers supplying nonlinear loads should be checked periodically to verify operation within acceptable limits. Transformers are also critical to the integrity of the grounding system.
Power Factor: What it is and How to Calculate it
What is power factor and why is it important? Learn how to calculate the power factor formula, each component of the equation, and why it matters.
溫度測試
振動
3 ways to improve motor health with vibration testing
One would be hard-pressed to find a facility manager who doesn’t want maintenance operations to run as smoothly as possible. Detecting signs of motor components failure becomes easier when combined with a preventive vibration program.
Understanding Vibration Monitoring and Analysis
Vibration testing for condition-based maintenance, to reduce costs and production losses. Mechanics of testing, analyzing roller bearing faults.