Levels of Calibration Services
The difference in the levels of service are with how information is reported to meet the customer’s needs. There is not a difference in the traceability provided as stated in the paragraph above. The term “Traceable” has been used in the past to define a specific level of service, but this is not appropriate considering all Fluke calibrations are traceable. All accredited calibrations meet the requirements of ISO/IEC 17025:2017. All facilities performing non-accredited calibrations are registered and meet the requirements of ISO9001 per the Conformance section above.
Statement of calibration practices
Delivered or referenced for new some products, this is not a calibration certificate but a statement that the product was calibrated and is traceable per the traceability statement above.
Non accredited calibration without data
Your instrument is calibrated to manufacturer’s specifications using test equipment traceable to the International System of Units (SI) through National Metrological Institutes, ratiometric techniques or natural physical constants. It is returned with a Certificate of Calibration, calibration sticker, and seals.
Non accredited calibration with data
Your instrument is calibrated to manufacturer’s specifications using test equipment traceable per the traceability statement above. It may be offered to be in conformance with ANSI/NCSL Z540-1 1994 and returned with a “Report of Calibration” with “as found” and “as left” readings and includes test accuracy ratios (TUR) where applicable (if less than 4:1). Cal stickers and calibration void if broken seals are included.
Accredited calibration
This calibration is done under the guidelines of an accrediting body (NVLAP, A2LA, CLAS, UKAS and more) to ISO/IEC 17025:2017 standard and will be delivered with documentation according to the accrediting body.
Functional test (Performance test)
After a repair a performance test is carried out to validate that the instrument is fully functional. No calibration certificate or associated material is provided.
Service Matrix
| Level of service output | Functional test | Non-accredited calibration without data | Non-accredited calibration with data | ANSI/NCSL Z540.1 | ISO 17025 accredited calibration |
| Validate instrument is functioning after repair | ? | ? | ? | ? | ? |
| Tamper-proof seals | ? | ? | ? | ? | ? |
| Calibration sticker | ? | ? | ? | ? | ? |
| Calibrated to manufacturer's specification with equipment traceable to the SI | ? | ? | ? | ? | ? |
| Certificate of calibration | ? | ? | ? | ? | ? |
| As-found and as-left data | ? | ? | ? | ? | ? |
| Apply decision rules for statements of conformity | ? | ? | ? | ? | ? |
| Identify TURs < 4:1 | ? | ? | ? | ? | ? |
| Measurement uncertainties | ? | ? | ? | ? | ? |
Calibration for Fluke Products
To check if your product is eligible for calibration, request a calibration quote, or schedule a service order for repair or calibration, please visit:
or to see if your instrument is supported for calibration:
Call us:?
800-94-FLUKE (800-943-5853)
Email us:?
service@fluke.com
Calibration for Fluke Calibration Products
To check if your product is eligible for calibration, request a calibration quote, or schedule a service order for repair or calibration, please visit:
or to see if your instrument is supported for calibration:
Call us:?
1-877-355-3225
Email us:?
service@flukecal.com